WORKING SETPOINT SETTING
The working setpoint is programmable within the lim-
its established with the parameters r1 and r2.
To modify the working setpoint value:
a) keep pushed the key
the instrument displays the actual value
the compressor LED flashes quickly
b) push and release the key or as long
as the instrument displays the desired value
the working setpoint value gets increased or decreased
c) after the modify release the key last
the instrument automatically turns out from the working
setpoint setting procedure.
CONFIGURATION PARAMETERS SETTING
Configuration parameters are arranged on two levels.
To gain access to the first level:
a) keep pushed for four seconds at least the keys
and
passed four seconds the instrument displays the label
PA
To select a parameter:
a) push and release the key or as long
as the instrument displays the label of the de-
sired parameter
To modify a parameter value:
a) keep pushed the key
the instrument displays the actual value
b) push and release the key or as long
as the instrument displays the desired value
the parameter value gets increased or decreased
c) after the modify release the key last
the instrument displays the label of the parameter again
To gain access to the second level:
a) enter inside the first level and select the label
PA
b) keep pushed the key
the instrument displays the actual value
c) push and release the key or as long
as the instrument displays -19
the label value gets increased or decreased
d) after the modify release the key last
the instrument displays the label PA again
e) keep pushed for four seconds at least the keys
and
passed four seconds the instrument displays the first pa-
rameter of the second level
To turn out from the configuration parameters
setting procedure:
a) keep pushed for four seconds at least the keys
and or do not operate with the keys
for fifty seconds at least.
ENGLISH
EC 6-294EC 6-294
EC 6-294EC 6-294
EC 6-294
Quick reference
14
communication
n0 0 2 --- 0 instrument functioning in the network (®)
n1 0 8 --- 0 instrument address (®)
n3 0 1 --- 0 enabling to work as slave instrument (§) (®)
n4 0 240 sec. 0 delay to the resources implementation in the slave instrument (®)
nA 0 15 --- 0 resources to implement in the slave instrument (®)
Additional informations:
the symbol (§) indicates that the parameter is of the first level
the symbol (*) indicates that the unit of measure depends from the parameter /8
the symbol (®) indicates that the parameter is available on request only
the symbol (**) indicates that the unit of measure depends from the parameter db.
EVERY CONTROL S.r.l.
Via Mezzaterra 6, 32036 Sedico Belluno ITALY
Phone 0039-0437-852468 (a.r.) Fax 0039-0437-83648
Internet addresses
http://www.everycontrol.it
Page view 4
1 2 3 4 5 6

Comments to this Manuals

No comments