Evco EVK412 User Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
EVCO S.p.A. This document belongs to Evco; unless you are authorized by Evco, you can not publish it.
Via Mezzaterra 6, 32036 Sedico Belluno ITALY Evco does not take any responsibility about features, technical data and possible mistakes related in this document or coming by its use.
Phone +39-0437-852468 • Fax +39-0437-83648 Evco does not take any responsibility about damages coming by the non-observance of the additional information.
[email protected] • www.evco.it Evco reserves the right to make any change without prior notice and at any time without prejudice the basic safety and operating features.
PT • 45/10
The instrument must be disposed according to the local legislation about the collection
for electrical and electronic equipment.
Lo strumento deve essere smaltito secondo le normative locali in materia di raccolta
delle apparecchiature elettriche ed elettroniche.
Das Gerät von der Spannungsversorgung trennen.
Sicherstellen, dass der Defaultwert der Parameter zweck-
mäßig ist, insbesondere prüfen, ob die Fühler vom Typ NTC
sind.
5 ANZEIGEN
5.1 Anzeigen
LED BEDEUTUNG
out 1 LED Abnehmer 1
Wenn eingeschaltet, ist Abnehmer 1 aktiv
Wenn blinkend:
Änderung des ersten Betriebssollwertes im Gange
Abnehmerschutz aktiv (Parameter C1 und C2)
out 2 LED Abnehmer 2
Wenn eingeschaltet, ist Abnehmer 1 aktiv
Wenn blinkend:
Änderung des zweiten Betriebssollwertes im Gange
Abnehmerschutz aktiv (Parameter C7 und C8)
Alarm-LED
Wenn eingeschaltet, ist ein Alarm aktiv
°C LED Grad Celsius
Wenn eingeschaltet, ist die Maßeinheit der Temperatur auf
Grad Celsius eingestellt (Parameter P2)
°F LED Grad Fahrenheit
Wenn eingeschaltet, ist die Maßeinheit der Temperatur auf
Grad Fahrenheit eingestellt (Parameter P2)
CODE BEDEUTUNG
Loc Tastatur und/oder Betriebssollwerte gesperrt (Parameter r3
und/oder r9); siehe Punkt 2.4
6 ALARME
6.1 Alarme
CODE BEDEUTUNG
AL1 Erster Temperaturalarm
Behebung:
Umgebungstemperatur prüfen
Siehe Parameter A1 e A3
Folgen:
Das Gerät arbeitet normal weiter
AL2 Zweiter Temperaturalarm
Behebung:
Umgebungstemperatur prüfen
Siehe Parameter A5 und A7
Folgen:
• Das Gerät arbeitet normal weiter
Sobald die Ursache, die den Alarm ausgelöst hat, behoben ist, wird der
Normalbetrieb wieder aufgenommen.
7 INTERNE DIAGNOSE
7.1 Interne Diagnose
CODE BEDEUTUNG
Pr1 Fehler Umgebungstemperaturfühler
Behebung:
Siehe Parameter P0
Korrekte Funktion des Fühlers prüfen
Verbindung zwischen Gerät und Fühler überprüfen
Umgebungstemperatur überprüfen
Folgen:
•Der Betrieb von Abnehmer 1 hängt vom Parameter C6 ab
•Der Betrieb von Abnehmer 1 hängt vom Parameter C10
ab
Sobald die Ursache, die den Alarm ausgelöst hat, behoben ist, wird der
Normalbetrieb wieder aufgenommen.
8 TECHNISCHE DATEN
8.1 Technische Daten
Gehäuse: selbstlöschend, grau.
Schutzgrad Frontseite: IP 65.
Anschlüsse (Einzige in Kupfer Leit): Schraubklemmleisten
(Spannungsversorgung, Eingang und Ausgänge), 6-poliger Steck-
verbinder (serieller Port, auf Anfrage); herausziehbare Klemmleisten
(Spannungsversorgung, Eingang und Ausgänge) auf Anfrage.
Betriebstemperatur: 0 bis 55 °C (10 ... 90% relative Feuchte, nicht
kondensierend).
Spannungsversorgung: 230 VAC, 50/60 Hz, 3 VA (Näherungs-
werte); 115 VAC oder 12-24 VAC/DC oder 12 VAC/DC auf Anfrage.
Isolationsklasse: 2.
Alarmsummer: auf Anfrage.
Messeingänge: 1 (Umgebungstemperaturfühler) für PTC-/NTC-Son-
den.
Messbereich: -50,0 bis 150,0 °C bei PTC-Fühlern, -40,0 bis 105,0 °C
bei NTC-Fühlern.
Auflösung: 0,1 °C/1 °C/1 °F.
Digitalausgänge: 2 Relais:
Relais Abnehmer 1: 16 A Widerst. bei
250 VAC, 5 FLA, 30 LRA (Wechselkontakt)
Relais Abnehmer 2: 8 A Widerst. bei
250 VAC, 2 FLA, 12 LRA (Wechselkontakt).
Der zulässige Maximalstrom am Abnehmer beträgt 10 A.
Serieller Port: Schnittstelle für die Kommunikation mit dem
Überwachungssystem (über den seriellen Port, mit TTL und dem
Kommunikationsprotokoll MODBUS) oder dem Programmierschlüssel
(auf Anfrage).
GB ENGLISH
9 WORKING SETPOINTS AND CONFIGURATION PARAMETERS
9.1 Working setpoints
MIN. MAX. U.M. DEF. WORKING SETPOINTS
r1 r2 °C/°F (1) 0.0 first working setpoint
r7 r8 °C/°F (1) 0.0 second working setpoint
9.2 Configuration parameters
PARAM. MIN. MAX. U.M. DEF. WORKING SETPOINTS
SP1 r1 r2 °C/°F (1) 0.0 first working setpoint
SP2 r7 r8 °C/°F (1) 0.0 second working setpoint
PARAM. MIN. MAX. U.M. DEF. MEASURE INPUTS
CA1 -25.0 25.0 °C/°F (1) 0.0 room probe offset
P0 0 1 - - - 0 kind of probe
0 = PTC
1 = NTC
P1 0 1 - - - 1 decimal point Celsius degree (for the quantity to
show during the normal operation)
1 = YES
P2 0 1 - - - 0 unit of measure temperature (2)
0=°C
1=°F
P5 0 1 - - - 0 quantity to show during the normal operation
0 = room temperature
1 = first working setpoint
PARAM. MIN. MAX. U.M. DEF. REGULATORS
r0 0.1 99.0 °C/°F (1) 2.0 if CFG = 1 or 2, first working setpoint differential
if CFG = 3, differential of the load working for cool-
ing (load 1)
r1 -99.0 r2 °C/°F (1) 0.0 minimum first working setpoint
r2 r1 (3) °C/°F (1) 150.0 maximum first working setpoint
r3 0 1 - - - 0 locking the first working setpoint modification (with
the procedure related in paragraph 4.1)
1 = YES
r5 0 1 - - - 1 if CFG = 1 or 2, cooling or heating action load 1
if CFG = 4, cooling or heating action loads
0 = cooling
r6 0.1 99.0 °C/°F (1) 2.0 if CFG = 1 or 2, second working setpoint differential
if CFG = 3, differential of the load working for heat-
ing (load 2)
r7 -99.0 r8 °C/°F (1) 0.0 minimum second working setpoint
r8 r7 (3) °C/°F (1) 150.0 maximum second working setpoint
r9 0 1 - - - 0 locking the second working setpoint modification
(with the procedure related in paragraph 4.2)
1 = YES
D DEUTSCH
9 BETRIEBSSOLLWERTE UND
KONFIGURATIONSPARAMETER
9.1 Betriebssollwerte
BETRIEBSSOLLWERTE
Erster Betriebssollwert
Zweiter Betriebssollwert
9.2 Konfigurationsparameter
BETRIEBSSOLLWERTE
Erster Betriebssollwert
Zweiter Betriebssollwert
MESSEINGÄNGE
Offset Umgebungstemperaturfühler
Fühlertyp
0 = PTC
1 = NTC
Dezimalpunkt Grad Celsius (für den im Normal-
betrieb angezeigten Wert)
1=JA
Maßeinheit Temperatur (2)
0=°C
1=°F
Im Normalbetrieb angezeigter Wert
0 = Umgebungstemperatur
1 = erster Betriebssollwert
REGLER
Wenn CFG = 1 oder 2, abh. vom ersten Betriebs-
sollwert
Wenn CFG = 3, Differenz des Abnehmers im Kühl-
betrieb (Abnehmer 1)
Betriebsmindestsollwert
Betriebshöchstsollwert
Änderungssperre des ersten Betriebssollwerts (mit
dem in Punkt 4.1 beschriebenen Verfahren)
1=JA
Wenn CFG = 1 oder 2, Kühl- oder Heizbetrieb des
Abnehmers 1
Wenn CFG = 4, Kühl- oder Heizbetrieb der Abneh-
mer
0 = Kühlbetrieb
Wenn CFG = 1 oder 2, Differenz des zweiten
Betriebssollwertes
Wenn CFG = 3, Differenz des Abnehmers im Heiz-
betrieb (Abnehmer 2)
Betriebsmindestsollwert
Betriebshöchstsollwert
Änderungssperre des zweiten Betriebssollwerts (mit
dem in Punkt 4.2 beschriebenen Verfahren)
1=JA
r10 0 1 - - - 1 cooling or heating action load 2 (only if CFG = 1 or
2)
0 = cooling
r11 1.0 (3) °C/°F (1) 5.0 if CFG = 3, neutral zone value
if CFG = 4, value of two steps
PARAM. MIN. MAX. U.M. DEF. LOADS PROTECTIONS
C1 0 240 min 0 minimum time between two activations in succes-
sion of load 1; also load 1 delay since the end of the
room probe error (4)
C2 0 240 min 0 minimum time load 1 remains turned off; also
load 1 delay since you turn on the instrument
C3 0 240 s 0 minimum time load 1 remains turned on
C6 0 1 - - - 0 load 1 activity during the room probe error
0 = turned off
1 = turned on
C7 0 240 min 0 minimum time between two activations in succes-
sion of load 2; also load 2 delay since the end of the
room probe error (4)
C8 0 240 min 0 minimum time load 2 remains turned off; also
load 1 delay since you turn on the instrument
C9 0 240 s 0 minimum time load 2 remains turned on
C10 0 1 - -- 0 load 2 activity during the room probe error
0 = turned off
1 = turned on
PARAM. MIN. MAX. U.M. DEF. TEMPERATURE ALARMS
A1 -99.0 (3) °C/°F (1) 0.0 temperature the first temperature alarm is activated;
also look at A3 (5)
A2 0 240 min 0 first temperature alarm delay
A3 0 4 - - - 0 kind of first temperature alarm
0 = alarm not enabled
1 = absolute lower alarm (or A1)
2 = absolute upper alarm (or A1)
3 = lower alarm relative to the first working setpoint
(or "first working setpoint - A1”; consider A1 with-
out sign)
4 = upper alarm relative to the first working setpoint
(or "first working setpoint + A1”; consider A1
without sign)
A4 0 240 min 0 temperature alarms delay since an independent
working setpoint modification
A5 -99.0 (3) °C/°F (1) 0.0 temperature the second temperature alarm is acti-
vated; also look at A7 (5)
A6 0 240 min 0 second temperature alarm delay
A7 0 4 - - - 0 kind of second temperature alarm
0 = alarm not enabled
1 = absolute lower alarm (or A5)
2 = absolute upper alarm (or A5)
3 = lower alarm relative to the second working
setpoint (or "second working setpoint - A5”; con-
sider A5 without sign) (6)
4 = upper alarm relative to the second working
setpoint (or "second working setpoint + A5”;
consider A5 without sign) (6)
PARAM. MIN. MAX. U.M. DEF. SERIAL NETWORK (MODBUS)
LA 1 247 - - - 247 instrument address
Lb 0 3 - - - 2 baud rate
0 = 2,400 baud
1 = 4,800 baud
2 = 9,600 baud
3 = 19,200 baud
LP 0 2 - - - 2 parity
0 = none
1 = odd
2 = even
PARAM. MIN. MAX. U.M. DEF. RESERVED
E9 0 1 - - - 1 reserved
PARAM. MIN. MAX. U.M. DEF. OPERATION
CFG 1 4 - - - 1 operation
1 = the first working setpoint is independent and
the second one is relative to the first
2 = two independent working setpoints
3 = neutral zone
4 = two steps
(1) the unit of measure depends on parameter P2
(2) set the parameters related to the regulators appropriately after the
modification of the parameter P2
(3) the value depends on parameter P2 (150.0 °C or 300 °F)
(4) if the parameter has value 0, the delay since the end of the room probe error will
however be 2 min
(5) the differential of the parameter is 2.0 °C/4 °F
(6) if parameter CFG has value 1, 3 or 4, the second temperature alarm will be relative to
the first working setpoint (because the first working setpoint is relative to the first or it is
not available).
Kühl- oder Heizbetrieb des Abnehmers 2 (nur wenn
CFG = 1 oder 2)
0 = Kühlbetrieb
Wenn CFG = 3, Wert des Neutralbereichs
Wenn CFG = 4, Wert der zwei Stufen
ABNEHMERSCHUTZ
Mindestzeit zwischen zwei aufeinander folgenden
Einschaltvorgängen des Abnehmers 1; auch Ver-
zögerung Abnehmer 1 ab Ende Fehler
Umgebungstemperaturfühler (4)
Mindestzeit, für die Abnehmer 1 ausgeschaltet bleibt;
auch Verzögerung des Abnehmers 1 nach dem
Einschalten des Geräts
Mindestzeit, für die Abnehmer 1 eingeschaltet bleibt
Aktivität Abnehmer 1 bei Fehler Umgebungs-
temperaturfühler
0 = ausgeschaltet
1 = eingeschaltet
Mindestzeit zwischen zwei aufeinander folgenden
Einschaltvorgängen des Abnehmers 2; auch Ver-
zögerung des Abnehmers 2 ab Ende Fehler
Umgebungstemperaturfühler (4)
Mindestzeit, für die Abnehmer 2 ausgeschaltet bleibt;
auch Verzögerung des Abnehmers 2 nach dem
Einschalten des Geräts
Mindestzeit, für die Abnehmer 2 eingeschaltet bleibt
Aktivität Abnehmer 2 bei Fehler Umgebungs-
temperaturfühler
0 = ausgeschaltet
1 = eingeschaltet
TEMPERATURALARME
Temperatur, bei deren Erreichen der erste
Temperaturalarm ausgelöst wird; siehe auch A3 (5)
Verzögerung erster Temperaturalarm
Art des ersten Temperaturalarms
0 = kein Alarm
1 = absoluter Mindesttemperaturalarm (A1)
2 = absoluter Höchsttemperaturalarm ( A1)
3 = relativer Mindesttemperaturalarm Betriebs-
sollwert 1 (d.h. „erster Betriebssollwert - A1“;
A1 ohne Vorzeichen)
4 = relativer Höchsttemperaturalarm Betriebs-
sollwert 1 (d.h. „erster Betriebssollwert + A1“;
A1 ohne Vorzeichen)
Verzögerung der Temperaturalarme nach Ände-
rung eines unabhängigen Betriebssollwertes
Temperatur, bei deren Erreichen der zweite
Temperaturalarm ausgelöst wird; siehe auch A7 (5)
Verzögerung des zweiten Temperaturalarms
Art des zweiten Temperaturalarms
0 = kein Alarm
1 = absoluter Mindesttemperaturalarm (A5)
2 = absoluter Höchsttemperaturalarm (A5)
3 = relativer Mindesttemperaturalarm Betriebs-
sollwert 2 (d.h. „zweiter Betriebssollwert - A5“;
A5 ohne Vorzeichen) (6)
4 = relativer Höchsttemperaturalarm Betriebs-
sollwert 2 (d.h. „zweiter Betriebssollwert + A5“;
A5 ohne Vorzeichen) (6)
SERIELLES NETZWERK (MODBUS)
Geräteadresse
Baudrate
0 = 2.400 Baud
1 = 4.800 Baud
2 = 9.600 Baud
3 = 19.200 Baud
Parität
0 = keine Parität
1 = ungerade
2 = gerade
RESERVIERT
Reserviert
BETRIEB
Betrieb
1 = erster Betriebssollwert unabhängig und zwei-
ter abhängig vom ersten
2 = beide Betriebssollwerte unabhängig
3 = Neutralbereich
4 = Zweistufenbetrieb
(1) Die Maßeinheit hängt vom Parameter P2 ab
(2) Nach Änderung des Parameters P2
müssen die Parameter der Regler kor-
rekt eingestellt werden
(3) Der Wert ist vom Parameter P2 abhängig
(150,0 °C oder 300 °F)
(4) Ist der Parameter auf 0 eingestellt, beträgt die
Verzögerung der Fehlerauslösung des
Umgebungstemperaturfühlers in jedem Fall
2 min
(5) Die Parameterdifferenz beträgt 2,0 °C/4 °F
(6) Ist der Parameter CFG auf 1, 3 oder 4 einge-
stellt, hängt der zweite Temperaturalarm vom
ersten Betriebssollwert ab (weil der zweite
Betriebssollwert vom ersten abhängt oder
nicht verfügbar ist).